G.711 Fax and Modem Transport Mode
                                            In this mode, when the terminating device detects fax or modem signals (CED or AnsAM), it sends a re-INVITE message to the originating device, requesting it to re-open the channel in G.711 VBD with the following adaptations:
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | Silence Compression = off | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | Echo Canceller Non-Linear Processor Mode = off | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | Dynamic Jitter Buffer Minimum Delay = 40 | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | Dynamic Jitter Buffer Optimization Factor = 13 | 
                                            
                                            After a few seconds upon detection of fax V.21 preamble or super G3 fax signals, the device sends a second re-INVITE enabling the echo canceller (the echo canceller is disabled only on modem transmission).
                                            A ‘gpmd’ attribute is added to the SDP according to the following format:
                                            a=gpmd:8 vbd=yes;ecan=on (or off for modems)
                                            a=gpmd:0 vbd=yes;ecan=on (or off for modems)
                                            The following parameters are ignored and automatically set to Events Only:
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | 'Fax Transport Mode' [FaxTransportMode] | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | 'Vxx ModemTransportType' [VxxModemTransportType] | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ➢ | To configure fax / modem transparent mode: | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | 1. | Open the Gateway General Settings page (Setup menu > Signaling & Media tab > Gateway folder > Gateway General Settings), and then from the 'Fax Signaling Method' drop-down list (IsFaxUsed), select G.711 Transport: | 
                                            
                                            
                                                